# Action-aware constraint pilot v2 amendment Status: **FROZEN AFTER V1 CONTROLLER STOP AND BEFORE V2 GPU RUNS**. Date: 2026-07-14 (Asia/Singapore). The V1 configuration matrix and every scientific gate remain unchanged. V2 fixes one controller bug and reruns every configuration and repetition fresh. ## V1 controller failure The MNS64/MBBT2048 burn-in completed all 510 requests in 61.259 seconds, below the frozen 90-second operational limit. However, the controller accidentally assigned the preceding 16-request warm-up result to `burnin_result`; its state therefore recorded 4.376 seconds and evaluated the wrong object. The first measured replay was terminated after 75 seconds, before it produced a result. No target configuration had started. V1 consumed 0.3184109431 H20-hours and contributes no action label or telemetry to V2. ## V2 correction and regression gate - The completed burn-in `run_client()` return value is assigned to `burnin_result`. - A dedicated `burnin_gate()` rejects any non-anchor object, any request count other than 510, and elapsed time above 90 seconds. - Unit tests explicitly pass a warm-up object and require rejection, then test accepted and over-limit burn-ins. - All five configs and 15 measured runs use a new run root; no V0/V1 runtime artifact is reused. V0 and V1 together consumed 0.7043978426 H20-hours. V2's incremental hard cap is therefore 7.2956021574 H20-hours, preserving the original global 8.0 H20-hour cap. The authoritative accounting file is `runs/action-aware-v0/prior-attempts-v2.json`.